Additional information
Cross Reference | 1179, 1302, 4033, 4074, R8184G |
---|
Oil primary, Intermittent Ignition, flame sensing circuit, 30 sec, safety switch, reset button
Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state flame sensing circuit . LED on terminal strip indicates system lockout. Enclosed safety switch with external reset button. Mounts on standard 4″ x 4″ junction box select models may be mounted directly on burner housing. 69-45610 Cadmium Sulfide Flame Detector and 24 VAC thermostat required. Direct replacement for popular competitive models.
Ignition Type: Intermittent Timing, Safety Switch: 15, 30 or 45 seconds. Mounting Bracket: For mounting on a standard 4″ × 4″ junction box or direct mounting on burner housing. Electrical Rating Contacts (full load): 7.4 A @ 120 VAC 3.7 A @ 240 VAC | Electrical Rating Contacts (locked rotor): 44.4 A @ 120 VAC 22.2 A @ 240 VAC. Dimensions: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep | 111 mm high x 104 mm wide x 64 mm deep. Temperature Range: -30°F to +130°F. Approvals – Underwriters Laboratories Inc.
Cross Reference | 1179, 1302, 4033, 4074, R8184G |
---|
HS Code | Country Of Origin | NAFTA Preference Criterion | NAFTA Producer Index |
---|---|---|---|
0 | __ |